The object of the tender process is Triple quadrupole mass spectrometer ICP-MS/MS.
Basic use of a mass spectrometer is to analyze element concentrations in a sample based on the mass-to-charge ratios of the ionized elements. There are several different types of mass-spectrometers available that differ in methods of sample introduction and analysis type. The required mass spectrometer in this procurement is a triple quadrupole mass spectrometer: ICP-MS/MS
The intended use of the triple quadrupole mass spectrometer is for the analysis of hard to determine radionuclides and trace element analysis in the semiconductor industry. Procured mass spectrometer must fulfill the requirements set for these types of analyses.
A triple quadrupole ICP-MS (Inductively Coupled Plasma Mass Spectrometer) is a type of mass spectrometer that uses a combination of three quadrupole mass filters to separate and analyze ions based on their mass-to-charge ratio (m/z). The instrument consists of an ion source, a mass analyzer, and a detector. The ion source generates a plasma by ionizing a sample using an inductively coupled plasma (ICP) source. The plasma produces a stream of ions that are extracted and focused into a beam using a series of lenses and skimmers. The ions are then introduced into the first quadrupole mass filter, which acts as a mass analyzer and selects ions of a specific mass-to-charge ratio (m/z) to pass through to the second quadrupole. In the second quadrupole, the selected ions are further filtered based on their m/z ratio, and only ions of a specific m/z ratio are allowed to pass through to the third quadrupole. The third quadrupole acts as a collision cell, where the selected ions are fragmented by collision with a gas, typically oxygen, helium or argon. The resulting fragments are then analyzed by the third quadrupole, which selects ions of a specific m/z ratio to pass through to the detector.
The detector measures the number of ions that reach it and generates a signal that is proportional to the concentration of the element in the sample. The signal is then processed by a computer to generate a mass spectrum, which shows the relative abundance of ions at different m/z ratios.
The object of the tender process is described in more detail in the invitation to tender documents.
Määräaika
Tarjousten vastaanottamisen määräaika oli 2023-09-21.
Hankinta julkaistiin 2023-08-17.
Kohde Hankinnan laajuus
Otsikko: Triple quadrupole mass spectrometer, ICP-MS/MS
Reg. no 43/206/2023
Tuotteet/palvelut: Laboratoriolaitteet, optiset ja tarkkuuslaitteet (lukuun ottamatta silmälaseja)📦
Lyhyt kuvaus:
“The object of the tender process is Triple quadrupole mass spectrometer ICP-MS/MS.
Basic use of a mass spectrometer is to analyze element concentrations in...”
Lyhyt kuvaus
The object of the tender process is Triple quadrupole mass spectrometer ICP-MS/MS.
Basic use of a mass spectrometer is to analyze element concentrations in a sample based on the mass-to-charge ratios of the ionized elements. There are several different types of mass-spectrometers available that differ in methods of sample introduction and analysis type. The required mass spectrometer in this procurement is a triple quadrupole mass spectrometer: ICP-MS/MS
The intended use of the triple quadrupole mass spectrometer is for the analysis of hard to determine radionuclides and trace element analysis in the semiconductor industry. Procured mass spectrometer must fulfill the requirements set for these types of analyses.
A triple quadrupole ICP-MS (Inductively Coupled Plasma Mass Spectrometer) is a type of mass spectrometer that uses a combination of three quadrupole mass filters to separate and analyze ions based on their mass-to-charge ratio (m/z). The instrument consists of an ion source, a mass analyzer, and a detector. The ion source generates a plasma by ionizing a sample using an inductively coupled plasma (ICP) source. The plasma produces a stream of ions that are extracted and focused into a beam using a series of lenses and skimmers. The ions are then introduced into the first quadrupole mass filter, which acts as a mass analyzer and selects ions of a specific mass-to-charge ratio (m/z) to pass through to the second quadrupole. In the second quadrupole, the selected ions are further filtered based on their m/z ratio, and only ions of a specific m/z ratio are allowed to pass through to the third quadrupole. The third quadrupole acts as a collision cell, where the selected ions are fragmented by collision with a gas, typically oxygen, helium or argon. The resulting fragments are then analyzed by the third quadrupole, which selects ions of a specific m/z ratio to pass through to the detector.
The detector measures the number of ions that reach it and generates a signal that is proportional to the concentration of the element in the sample. The signal is then processed by a computer to generate a mass spectrum, which shows the relative abundance of ions at different m/z ratios.
The object of the tender process is described in more detail in the invitation to tender documents.
1️⃣
Suorituspaikka: Manner-Suomi🏙️
Hankinnan kuvaus:
“The object of the tender process is Triple quadrupole mass spectrometer ICP-MS/MS (later also “Equipment”).
Basic use of a mass spectrometer is to analyze...”
Hankinnan kuvaus
The object of the tender process is Triple quadrupole mass spectrometer ICP-MS/MS (later also “Equipment”).
Basic use of a mass spectrometer is to analyze element concentrations in a sample based on the mass-to-charge ratios of the ionized elements. There are several different types of mass-spectrometers available that differ in methods of sample introduction and analysis type. The required mass spectrometer in this procurement is a triple quadrupole mass spectrometer: ICP-MS/MS
The intended use of the triple quadrupole mass spectrometer is for the analysis of hard to determine radionuclides and trace element analysis in the semiconductor industry. Procured mass spectrometer must fulfill the requirements set for these types of analyses.
A triple quadrupole ICP-MS (Inductively Coupled Plasma Mass Spectrometer) is a type of mass spectrometer that uses a combination of three quadrupole mass filters to separate and analyze ions based on their mass-to-charge ratio (m/z). The instrument consists of an ion source, a mass analyzer, and a detector. The ion source generates a plasma by ionizing a sample using an inductively coupled plasma (ICP) source. The plasma produces a stream of ions that are extracted and focused into a beam using a series of lenses and skimmers. The ions are then introduced into the first quadrupole mass filter, which acts as a mass analyzer and selects ions of a specific mass-to-charge ratio (m/z) to pass through to the second quadrupole. In the second quadrupole, the selected ions are further filtered based on their m/z ratio, and only ions of a specific m/z ratio are allowed to pass through to the third quadrupole. The third quadrupole acts as a collision cell, where the selected ions are fragmented by collision with a gas, typically oxygen, helium or argon. The resulting fragments are then analyzed by the third quadrupole, which selects ions of a specific m/z ratio to pass through to the detector.
The detector measures the number of ions that reach it and generates a signal that is proportional to the concentration of the element in the sample. The signal is then processed by a computer to generate a mass spectrum, which shows the relative abundance of ions at different m/z ratios.
The object of the tender process is described in more detail in the invitation to tender documents.
Näytä lisää Myöntämisperusteet
Hinta ei ole ainoa myöntämisperuste, ja kaikki perusteet ilmoitetaan ainoastaan hankinta-asiakirjoissa
Sopimuksen, puitesopimuksen tai dynaamisen hankintajärjestelmän kesto
Jäljempänä oleva aikataulu on ilmaistu kuukausina.
Kuvaus
Kesto: 12
Oikeudelliset, taloudelliset, rahoitukselliset ja tekniset tiedot Osallistumisehdot
Luettelo ja lyhyt kuvaus olosuhteista: As stated in the invitation to tender documents.
Taloudellinen ja rahoituksellinen asema
Luettelo ja lyhyt kuvaus valintaperusteista: Selection criteria as stated in the invitation to tender documents
Tekninen ja ammatillinen pätevyys
Luettelo ja lyhyt kuvaus valintaperusteista: Selection criteria as stated in the invitation to tender documents
Sopimukseen liittyvät ehdot
Sopimuksen täytäntöönpanoehdot: As stated in the invitation to tender documents.
Menettely Toimenpiteen tyyppi
Avoin menettely
Hallinnolliset tiedot
Tarjousten tai osallistumishakemusten vastaanottamisen määräaika: 2023-09-21
12:00 📅
Kielet, joilla tarjoukset tai osallistumishakemukset voidaan jättää: englanti 🗣️
Tarjouksen on oltava voimassa: 2023-12-31 📅
Tarjousten avaamista koskevat ehdot: 2023-09-21
12:30 📅
Tarjousten avaamista koskevat ehdot (Tiedot valtuutetuista henkilöistä ja avaamismenettelystä):
“The given date is preliminary. VTT reserves the right to change the scheduled date and time.
The opening of tenders shall not be a public event.”
Täydentävät tiedot Lisätietoja
“This notice has links and/or attachments listed in https://www.hankintailmoitukset.fi/en/public/procurement/91647/notice/134604” Arvostelurunko